When the capsule matters
Editorial

When the capsule matters

Nicolás Fiz

Arthroscopic Surgery Unit, Hospital Vithas San José, 01008 Vitoria-Gasteiz, Spain

Correspondence to: Nicolás Fiz. Arthroscopic Surgery Unit, Hospital Vithas San José, Calle del Beato Tomás de Zumárraga 10, 01008 Vitoria-Gasteiz, Spain. Email: nicofiz@yahoo.es.

Submitted Jan 31, 2015. Accepted for publication Feb 06, 2015.

doi: 10.3978/j.issn.2305-5839.2015.04.19


Hip arthroscopy can be considered an emerging technique that has been developed and is still developing rapidly. In recent years, the exponential increase in the number of arthroscopic hip surgery and continued development of technical variations push us to think about what and how, about the indications and techniques in addressing the hip pathology in young adults. Past difficulties to access and view the joint have given way to an increasingly advanced surgical refinement. In this new path, common sense should guide our steps, and the scientific evidence secures them.

Since before the explosion of hip arthroscopy, the anatomical and functional description of the hip joint and surrounding structures was performed exhaustively (1). However, the first steps in hip preservation surgery focused their efforts solely on the correction of bone deformities. Probably the technical difficulties were responsible for the initial capsulectomies that were performed to optimize the joint vision; in the same way, labral debridement was conducted to treat labral tears (2). Technology improvements and increased anatomical and functional knowledge of the labrum brought a change in the attitude of treatment; thus, more conservative measures have been imposed, improving functional outcomes of patients (3,4).

This is the same path that has been undertaken in more recent years to approach hip capsule: the way of preservation. In recent years it has increased the anatomical and functional knowledge of the capsule (5). We have to understand the joint as a whole organ, in which each of its parts plays a major role in joint function. One of the most relevant functions of capsule is to stabilize the joint that is accomplished through a multiple ligament complex (1); every part of it provides stability in the different planes of motion (6,7) being the most important the iliofemoral ligament. Moreover, this complex is the door of the joint vascularization and supports the synovium (8), which produces synovial fluid in order to maintain the cartilage homeostasis (9).

One of the problem emerged at the beginning of hip arthroscopy is that the capsule stood between the surgeon and the injury area, and correct vision was needed for proper correction of bone deformities, especially in CAM lesions. The easiest way to solve this obstacle was the partial excision of capsular tissue in the area of work or performed extensive capsulotomies. Frequently, bone deformities are often located in the anterolateral area, which corresponds to the capsular iliofemoral ligament, main hip stabilizer in extension. Consequently, this ligament was injured by the capsular defects created in this zone. Soon the results of such poor decisions were revealed. Several cases of macro-instability (10) and countless cases of micro-instability (11) (often underdiagnosed) roused the alarm. In addition, a complete view of the joint to achieve full correction of deformities was necessary. Therefore, the way was well defined: the view should be complete and the capsule preserved at maximum.

This premise has led to the current evolution of hip arthroscopic technique with two main trends in capsular handling: interportal capsulotomy and “T” capsulotomy. The former is little aggressive, but it is difficult to visualise extensive CAM-type deformities; hip flexion and rotation might help to improve the view in the peripheral compartment. However, in very large CAM deformities some degree of capsular debridement is needed, even if it is only performed in its deepest part and does not involve the full thickness. “T” capsulotomy provides an excellent view of the peripheral compartment but capsular repair, at least partially, needs to be performed to avoid iatrogenic instability (12,13). Nowadays most authors tend to repair the interportal capsulotomy (14) and as more patients are treated and analysed in studies, it seems obvious that full capsule repair offers the best clinical results (15).

In spite of this, residual deformity remains the most common cause of revision hip arthroscopy, suggesting that the problem of correct deformity visualisation is not completely resolved (16). Novel developed conservative techniques tend to preserve the capsule at maximum (17). Understanding the capsular-ligamentous complex beyond a purely mechanical structure, these techniques promote a “no capsulotomy” intervention with maximum respect to the mechanical and biological functions of the capsule. They involve an enormous surgical effort for the experienced surgeon, but clinical results are promising.

Maintaining complete capsular integrity during surgery preserves the periarticular tissues from iatrogenic injuries as well as minimizes fluid leakage, diminishing postoperative pain. Postoperative mobilization is not restricted as capsule repair with sutures is not needed; postoperative adhesions and fibrosis, a natural tissue repair process, are reduced. Evidence is still scarce but medical intuition is strong: we must preserve the joint as much as possible and protect the most anatomical structures.


Acknowledgements

Disclosure: The author declares no conflict of interest.


References

  1. Fuss FK, Bacher A. New aspects of the morphology and function of the human hip joint ligaments. Am J Anat 1991;192:1-13. [PubMed]
  2. Farjo LA, Glick JM, Sampson TG. Hip arthroscopy for acetabular labral tears. Arthroscopy 1999;15:132-7. [PubMed]
  3. Kelly BT, Weiland DE, Schenker ML, et al. Arthroscopic labral repair in the hip: surgical technique and review of the literature. Arthroscopy 2005;21:1496-504. [PubMed]
  4. Larson CM, Giveans MR. Arthroscopic debridement versus refixation of the acetabular labrum associated with femoroacetabular impingement. Arthroscopy 2009;25:369-76. [PubMed]
  5. Martin HD, Savage A, Braly BA, et al. The function of the hip capsular ligaments: a quantitative report. Arthroscopy 2008;24:188-95. [PubMed]
  6. Hidaka E, Aoki M, Izumi T, et al. Ligament strain on the iliofemoral, pubofemoral, and ischiofemoral ligaments in cadaver specimens: biomechanical measurement and anatomical observation. Clin Anat 2014;27:1068-75. [PubMed]
  7. Walters BL, Cooper JH, Rodriguez JA. New findings in hip capsular anatomy: dimensions of capsular thickness and pericapsular contributions. Arthroscopy 2014;30:1235-45. [PubMed]
  8. Kalhor M, Beck M, Huff TW, et al. Capsular and pericapsular contributions to acetabular and femoral head perfusion. J Bone Joint Surg Am 2009;91:409-18. [PubMed]
  9. Bedi A, Galano G, Walsh C, et al. Capsular management during hip arthroscopy: from femoroacetabular impingement to instability. Arthroscopy 2011;27:1720-31. [PubMed]
  10. Matsuda DK. Acute iatrogenic dislocation following hip impingement arthroscopic surgery. Arthroscopy 2009;25:400-4. [PubMed]
  11. Boykin RE, Anz AW, Bushnell BD, et al. Hip instability. J Am Acad Orthop Surg 2011;19:340-9. [PubMed]
  12. Bedi A, Kelly BT, Khanduja V. Arthroscopic hip preservation surgery: current concepts and perspective. Bone Joint J 2013;95-B:10-9. [PubMed]
  13. Harris JD, Slikker W 3rd, Gupta AK, et al. Routine complete capsular closure during hip arthroscopy. Arthrosc Tech 2013;2:e89-94. [PubMed]
  14. Domb BG, Philippon MJ, Giordano BD. Arthroscopic capsulotomy, capsular repair, and capsular plication of the hip: relation to atraumatic instability. Arthroscopy 2013;29:162-73. [PubMed]
  15. Frank RM, Lee S, Bush-Joseph CA, et al. Improved outcomes after hip arthroscopic surgery in patients undergoing T-capsulotomy with complete repair versus partial repair for femoroacetabular impingement: a comparative matched-pair analysis. Am J Sports Med 2014;42:2634-42. [PubMed]
  16. Ross JR, Larson CM, Adeoye O, et al. Residual Deformity Is the Most Common Reason for Revision Hip Arthroscopy: A Three-dimensional CT Study. Clin Orthop Relat Res 2015;473:1388-95. [PubMed]
  17. Fiz N, Sánchez M, Pérez JC, et al. A less-invasive technique for capsular management during hip arthroscopy for femoroacetabular impingement. Arthrosc Tech 2014;3:e439-43. [PubMed]
Cite this article as: Fiz N. When the capsule matters. Ann Transl Med 2015;3(S1):S30. doi: 10.3978/j.issn.2305-5839.2015.04.19

Download Citation